Introduction
975-0125-02-01 1–7
MS2000 Features
Front Panel Features
Before you begin to operate the MS2000, review the front panel features shown in
Figure 1-2 and described in Table 1-1. A detailed view of the lights and buttons on
the front panel is shown in Figure 1-3 and described in Table 1-2.
Figure 1-2
Front Panel of the MS2000
Table 1-1
Front Panel Features
Feature Description
1 AC wiring compartment access panel provides access to the terminal block for
wiring the AC input and AC output.
2 AC knockouts provide access for AC input and AC output wiring. A total of four
knockouts are provided on the unit: two on the front and one on each side (not
shown).
3 Mounting flanges are used for mounting the unit. A total of six flanges are
provided on the unit.
4 Fans are located on the top of the unit and the bottom of the unit.
• Top external fan is an intake fan that activates when the internal temperature of
the inverter/charger increases. The fan speed varies with the internal temperature
and turns off when the inverter/charger cools down. (This internal temperature
may be caused by heat in the inverter/charger or by high ambient temperature.)
• Bottom internal fan (not shown) is an exhaust fan and runs continuously if the
unit is inverting or charging.