Specifications
A2 975-0125-02-01
Inverter Specifications
All inverter specifications are at nominal conditions: ambient temperature of 77 °F
(
25 °C), 2000 watt resistive load, 12 volts DC inverting on the MS2000, 120 volts
AC, unless otherwise specified.
Table A-1
Inverter Specifications
Output wave form Sine wave
Total harmonic voltage distortion <3%
Output power continuous 2000 W/2000 VA continuous
Surge rating 5000 W/5000 VA for 5 seconds
AC output voltage 120 VAC ± 5%
Input DC voltage rating 12 VDC nominal, 10 to 16 VDC
AC output frequency 60.0 ± 0.05 Hz
Power factor (lag or lead) 0 to 1.0
Peak efficiency >89%
Efficiency at 2000W >85%
Load sense consumption <5 W
DC low voltage shutdown 10 volts
DC over voltage shutdown 16 volts
Vista de pagina 99