Comprehensive Electronic Protection
MS2000 is CSA approved to UL 458 (including the Marine Supplement) and
CSA C22.2 No. 107.1, and it is designed to American Boat and Yacht Council
(ABYC) recommended practices E-11 and A-25 for marine use. See Regulatory
Approvals on page A5 for more information.
MS2000 is equipped with numerous protection features to ensure safe operation.
Protection feature
Battery over-voltage
protection
Keeps the battery voltage from getting too high in
charge mode. Shuts the inverter off in invert mode.
Battery under-voltage
protection
Prevents inverter from discharging your batteries
too low. The inverter doesnt run if battery voltage is
too low.
Over-temperature
protection
Protects the unit from overheating by either derating
(charge mode) or by shutting down (invert mode).
See Invert Power Derating vs Ambient
Temperature on page A6.
Automatic over load
protection
Protects the unit from excessive loads. The unit will
provide 5000 watts (2.5 times of the rated load) for
up to 5 seconds, and then protect itself by shutting
down. See Specifications on page A2 for more
information.
Short circuit protection Detects short circuits and protects the unit by
shutting it down.